Insulate the pump house, then add a thermostat-controlled electric pump-house heater. Most have a 40°F lowest setting; the Water Systems Council says to keep the space above 40°F. A 500-watt unit costs about 9¢ an hour to run at the U.S. average rate.
What we did: We compared three pump-house heaters from their makers' manuals and spec sheets, weighed heat lamps and fuel heaters against published fire and CO warnings, and priced five heaters on one day.
⚠️ Safety. Never use a propane, kerosene or other fuel-burning heater in a closed pump house: CPSC warns that fuel-burning heating equipment “can produce CO, an odorless, colorless and deadly gas.” Heat lamps near straw, insulation scraps or a wood wall can start a fire. Hardwired heaters must be wired to code and grounded (Marley); have a licensed electrician add the circuit. Turn the power off at the panel before servicing.
What can freeze
| Part | Why it freezes first |
|---|---|
| Small tube or nipple under the pressure switch | Thin, holds little water. See pressure switch settings |
| Pressure tank, tee, gauge, drain valve | Sit near the floor and cold walls |
| Exposed pipe and the line through the wall | Coldest spots; wind leaks |
| Above-ground pump (jet pump) | Water in the pump case |
Water Systems Council: keep the space “above 40 degrees,” and put the pump “in an insulated enclosure” if it can drop below 32°F. The pump motor itself adds some heat inside an enclosure.
Heater options
| Option | Good for | Watch out |
|---|---|---|
| Thermostatic electric pump-house heater | Small, insulated pump house or utility room | Needs a proper circuit; mounting clearances; damp-location rating |
| Heat lamp or incandescent bulb | Not recommended as the only heat | No thermostat on its own; hot bulb near combustibles. NDSU Extension: secure with a locking chain, plug straight into a GFCI- and AFCI-protected outlet, no extension cord, check often |
| Heat tape | Individual exposed pipes | Follow the maker’s no-overlap and insulation rules |
| Insulated enclosure or cover, no heater | Mild climates; pump with some motor heat | Water Systems Council recommends foam rubber or fiberglass on casing and pipes |
| Propane, kerosene, gas heater | Never in a closed pump house | Carbon monoxide; flame near pump wiring |
Three pump-house heaters compared
From each maker’s manual or spec sheet.
| Marley / Qmark WHT500 (HT500) | King Electric U Series | Cadet FP Series | |
|---|---|---|---|
| Power | 500 W at 240 V; 375 W at 208 V; 500 W at 120 V (field rewire) | 62–1,000 W by model (U1250: 500 W at 120 V) | FP052TB 500/375 W, FP102TB 1,000/750 W at 240/208 V |
| Thermostat | Built-in, 40–70°F | Built-in, 40–90°F, plus over-temperature limit | Built-in dial, 40–85°F; wall thermostat not allowed |
| Mounting | Wall, horizontal only; 18 in. above floor, 12 in. below ceiling | Vertical (up to 500 W) or horizontal | 3 in. clear below, 12 in. above |
| Wet and damp | “Do not use” where it gets direct contact with water or in a corrosive environment | ETL listed for damp locations; -SS stainless option for high moisture | Not stated on the listing |
| Hookup | Hardwired, grounded, to code | Hardwired (7/8 in. knockout) | Hardwired, 6 in. leads |
Marley notes the WHT500 is built for “automatic, 24-hour protection,” and at its lowest setting may still come on if the room drops below 40°F. King says its U Series is “Designed to meet requirements outlined in ASSE-1060.”
Setting the thermostat
- Set it at or just above 40°F. That is the lowest setting on all three heaters above, and the Water Systems Council’s floor.
- Put the heater low and near the tank and switch, but keep its clearances. Don’t let it touch the tank, pipes or wiring.
- Check on the first cold night: the heater should cycle, and the switch tube should not frost.
- Keep a thermometer in the pump house. A cheap min/max one shows overnight lows.
What it costs to run
kWh = heater watts × hours on ÷ 1,000 Cost = kWh × your electricity price
EIA’s U.S. average residential price was 18.31¢/kWh in July 2026 (released 2026-09-24). Use your own bill’s rate if you can.
| Example (our arithmetic) | kWh | Cost at 18.31¢ |
|---|---|---|
| 500 W heater, 1 hour | 0.5 | $0.09 |
| 500 W, 8 hours a day for 30 days | 120 | $21.97 |
| 500 W, on 24 hours a day for 30 days (worst case) | 360 | $65.92 |
A thermostat runs it only when the room drops to its setting. Insulation cuts run time most.
What well house heaters cost
Zoro list prices, checked 2026-10-17. The same WHT500 model showed up at $166.00 and $348.99 under two listings.
| Heater | Watts / volts | Price |
|---|---|---|
| Qmark WHT500 | 500/376/500 W, 240/208/120 V | $166.00 |
| Dayton 2YV13 | 500/375/500 W, 120/208/240 V | $185.99 |
| TPI RPH15A | 500 W, 120 V | $295.99 · $401.99 (two listings) |
| Marley WHT500 | 500 W, 240/208 V or 120 V | $348.99 |
| King Electric U1250 / U1250-SS (stainless) | 500 W, 120 V | $539.99 / $1,408.99 |
If it already froze
- No water: follow the frozen-lines step in no water from well. Thaw with electric heat, never a flame.
- Cracked tank, switch or pipe: call a licensed well contractor or plumber (Water Systems Council).
- Outdoor tap that keeps freezing: check the drain gravel on your frost free hydrant.
FAQ
How do you keep a well from freezing? Insulate the pump house or well enclosure, wrap exposed pipe and casing, and keep the space above 40°F with a thermostat-controlled electric heater. A pitless adapter carries the water line out below the frost line. If it freezes anyway, call a licensed well contractor.
How do you keep a well pump from freezing? Protect what sits above ground: the pump if it’s a jet pump, the pressure tank, switch tube and pipes. Put them in an insulated enclosure with a pump-house heater set near 40°F; the motor adds some heat too. Never use a fuel-burning heater in a closed space.
Sources
- Water Systems Council (wellcare), “Winterizing and Protecting Pipes” — keep above 40°F; insulated enclosure; pump motor heat; call a licensed well contractor
- Marley Engineered Products, HT500 Surface Mounted Utility Heater Installation & Maintenance Instructions (HT500-Manual_2.24.20)
- Marley Engineered Products (Berko/Qmark), WHT500 Series Utility Well House Heater product page — 40–70°F, cETLus, 24-hour protection
- King Electrical Mfg., Pumphouse Heater U Series Engineering Specifications — 40–90°F, ETL damp locations, -SS stainless, ASSE-1060 (copy hosted by Zoro)
- More Electric Heating, Cadet FP Series frost protection heater listing — FP052TB/FP102TB, 40–85°F, clearances, no wall thermostat
- NDSU Extension, “Take precautions when using heat lamps for newborn livestock” (2023-03-02)
- U.S. CPSC, "Keep Warm and Safe This Winter: Tips for Using Generators, Furnaces and Space Heaters" (2026-01-23)
- U.S. EIA, Electric Power Monthly Table 5.6.A, residential average price, U.S. total, July 2026 (released 2026-09-24)
- Retail prices (checked 2026-10-17) — Zoro (Qmark WHT500, Marley WHT500, Dayton 2YV13, TPI RPH15A, King Electric U1250 and U1250-SS)
All sources checked 2026-10-17.
Method: heater specs, clearances and warnings come from each maker’s manual, spec sheet or product listing. Pump-house temperature and insulation advice come from the Water Systems Council; heat-lamp and fuel-heater risks from NDSU Extension and CPSC. Running costs are our arithmetic at EIA’s July 2026 average price. Prices are Zoro list prices from 2026-10-17. We have not installed or tested a pump house heater ourselves.
Editorial note: This page was researched and fact-checked by the County Road Home team against the manufacturer documents and public sources listed above. AI tools assisted with drafting; every number was checked by an editor before publishing. We are not licensed well contractors or electricians. For a new heater circuit, use a licensed electrician. Found an error? Email hello@countyroadhome.com and we will review it within 7 days. Last checked: 2026-10-17.